RX-V1900/HTR-6290/DSP-AX1900
■ AMP ADJUSTMENT / アンプ部調整
Confirmation of Idling Current of Amp Unit
● Right after power is turned on, confirm that the volt-
age across the terminals of R467 (SURROUND BACK
Rch), R468 (SURROUND Rch), R469 (FRONT Rch),
R470 (CENTER), R471 (FRONT Lch), R472 (SUR-
ROUND Lch), R473 (SURROUND BACK Lch) are be-
tween 0.1mV and 10.0mV.
● If it exceeds 10.0mV, open (cut off) R432 (SURROUND
BACK Rch), R433 (SURROUND Rch), R434 (FRONT
Rch), R435 (CENTER), R436 (FRONT Lch), R437
(SURROUND Lch), R438 (SURROUND BACK Lch)
and reconfirm the voltage.
Attention
If the measured voltage exceeds 10.0mV after an
amplifier repair, first check for a defective component
before cutting the bias resistor.
● Confirm that the voltage is 0.2 mV to 15.0 mV after 60
minutes.
0.1mV - 10.0mV
(DC)
R473
R472
R438
70
R467 (SURROUND BACK Rch)
R468 (SURROUND Rch)
R469 (FRONT Rch)
R470 (CENTER)
R471 (FRONT Lch)
R472 (SURROUND Lch)
R473 (SURROUND BACK Lch)
R471
R436
R437
MAIN (1) P.C.B.
アンプユニットのアイドリング電流の確認
● 電源投入直後、R467 (SURROUND BACK Rch) 、R468
(S U R R O U N D R c h) 、R469 ( F R O N T R c h ) 、R470
( CENTER ) 、R471 ( FRONT Lch ) 、R472 ( SURROUND
Lch ) 、R473 ( SURROUND BACK Lch )の端子間電圧
を測定し、0.1mV から 10.0mV の間であることを確認
してください。
● 電圧が 10mV を超えている場合は、R432 (SURROUND
BACK Rch) 、R433 (SURROUND Rch) 、R434 ( FRONT
Rch ) 、R435 ( CENTER ) 、R436 ( FRONT Lch ) 、R437
( SURROUND Lch ) 、R438 ( SURROUND BACK Lch )
をカットし、電圧を再確認してください。
注意
パワーアンプ修理後に 10.0mV を超えている場合は、
抵抗をカットする前に故障箇所を調べてください。
● 60 分後、電圧が 0.2mV ∼ 15.0mV であることを確認
してください。
Open (cut off)
カッ ト
R432 (SURROUND BACK Rch)
R433 (SURROUND Rch)
R434 (FRONT Rch)
R435 (CENTER)
R436 (FRONT Lch)
R437 (SURROUND Lch)
R438 (SURROUND BACK Lch)
FRONT
R470
R469
R435
R434
REAR
R467
R468
R433
R432