hit counter script
Honeywell GSMV4G Installation And Setup Manual

Honeywell GSMV4G Installation And Setup Manual

Intellipath series 4g gsm communicator
Table of Contents

Advertisement

800-11119 1/12 Rev. E
I
n
t
e
l
l
i
P
a
t
h
I
n
t
e
l
l
i
P
a
t
h
T
M
T
M
A
u
t
o
-
s
A
u
t
o
-
s
G
S
M
G
S
M
Installation and Setup Guide
S
e
r
i
e
s
4
G
G
S
e
r
i
e
s
4
G
G
e
l
e
c
t
s
O
p
t
i
m
u
m
e
l
e
c
t
s
O
p
t
i
m
u
m
V
4
G
/
G
V
4
G
/
G
S
M
C
o
m
m
u
S
M
C
o
m
m
u
G
S
M
p
a
t
h
2
G
G
S
M
p
a
t
h
2
G
S
M
V
C
S
M
V
C
s
u
p
p
o
r
t
s
t
w
o
s
u
p
p
o
r
t
s
t
w
o
n
i
c
a
t
o
r
n
i
c
a
t
o
r
,
3
G
,
o
r
4
G
,
3
G
,
o
r
4
G
N
4
G
N
4
G
-
w
a
y
v
o
i
c
e
-
w
a
y
v
o
i
c
e

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell GSMV4G

  • Page 1 – – Installation and Setup Guide 800-11119 1/12 Rev. E...
  • Page 3: Table Of Contents

    SECTION 2: Mounting and Wiring ........................ 2-1 Determine the Signal Strength and Select a Location ................2-1 Mounting the Communicator ........................2-2 Mounting Procedure, GSMV4G (no rear tamper switch) ............... 2-2 Mounting Procedure, GSMVCN4G (with rear tamper switch) ............. 2-3 Wiring the Communicator ........................2-4 Wiring for two-way voice ........................
  • Page 4 GSMV4G/GSMVCN4G Installation and Setup Guide Register using the Tamper Switch ....................4-2 Register using the Programming Tool ..................... 4-2 Replacing an existing communicator ....................4-3 Register by Phone ..........................4-3 SECTION 5: Programmer Keyboard Commands ..................5-1 Programmer Keyboard Commands ......................5-1 Identification Displays ........................
  • Page 5: Section 1: General Information

    Introduction Congratulations on your purchase of Honeywell's GSMV4G GSM Communicator (referred to as the GSMV4G, or GSMVCN4G in Canada). It represents the latest and most innovative communication technology for the security industry and uses sophisticated encryption to ensure the highest level of security for your customer.
  • Page 6: Encryption

    “Certificate number 979.” Remote Services Honeywell now offers a new series of web based services that provides consumers with the ability to communicate with their security system remotely in a number of ways. These new web services will allow users to: •...
  • Page 7: Zone Trigger Mode

    Opening and Closing ring back is supported by the control panel’s digital dialer. 4204 Mode and Two-4204 Mode • This mode is for use with Honeywell control panels that do not support ECP communica- tion, but do support 4204 Relay Modules •...
  • Page 8: Antenna

    GSMV4G/GSMVCN4G Installation and Setup Guide • Fault output: Terminal 11 can serve as a fail-safe trigger for communicator fault conditions. If used, the fault relay will trip when the following conditions occur: tamper*, power loss*, low battery*, battery charger fault*, loss of network connectivity*, the device is not registered and the device is remotely disabled by AlarmNet.
  • Page 9: Specifications

    (Honeywell transformer # 1361CN not included with the GSMVCN4G.) Current Drain: 220mA standby, 380mA active 6V, 3.1AH, (Honeywell # K14139 included with GSMV4G only.) Backup Battery: Expected Battery Life: 5 Years (approx.) Note: The sealed lead acid battery used for backup will have reduced life expectancy when exposed to elevated temperatures.
  • Page 10: Compatibility

    For UL installations and ULC Commercial Burglary Installations, any compatible UL or ULC (respectively) Listed Control Panel may be used. Note, that any control panel that does not communicate via Honeywell's ECP data bus is compatible using zone Trigger Mode. For ULC Commercial Fire Installations, only ULC Listed Subscriber's Unit Panels which use Honeywell's ECP data bus are compatible.
  • Page 11: Section 2: Mounting And Wiring

    S E C T I O N Mounting and Wiring • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • Determine the Signal Strength and Select a Location The communicator must be mounted indoors within the protected premises.
  • Page 12: Mounting The Communicator

    4. For Commercial Burglary installations, you must install the rear tamper switch. The cover must be secured with the supplied screw. Mounting Procedure, GSMV4G (no rear tamper switch) 1. Locate the case back over selected mounting position such that the opening in the case back is aligned with the wire/cable opening on the mounting surface.
  • Page 13: Mounting Procedure, Gsmvcn4G (With Rear Tamper Switch)

    Section 2: Mounting and Wiring Mounting Procedure, GSMVCN4G (with rear tamper switch) For Canadian installations where the rear tamper switch is used, this procedure requires the removal of the printed circuit boards and installation of the tamper screw. 1. Remove the two mounting screws, and standoff from the daughter card, as shown in Step A below.
  • Page 14: Wiring The Communicator

    The GSMV4G requires an optional audio cable (GSMV-AUDIO, grey) to support two-way voice using the AVS Base Unit. Note the AVS Base Unit is part of Honeywell’s AVS Audio Verification System. This system consist of the AVS Base Unit, Remote Station, and the Remote Station PC board.
  • Page 15: Wiring For Ecp, 4204 And Two-4204 Modes

    Check the Installation and Setup Guide for the control panel you are using to see if it supports ECP communication. Connect the communicator to a compatible Honeywell VISTA control panel's ECP terminals, in parallel with keypads and other peripheral devices such as RF receiver, VIP module, etc.
  • Page 16: Wiring The Fault Relay

    GSMV4G/GSMVCN4G Installation and Setup Guide Wiring the Zone 1 Input for a Ground (-V) Trigger • Zones should use EOL resistors, and be pro- grammed as V+ Inverted or V– Inverted operation such that a cut line results in an alarm.
  • Page 17: Power Connections And Options

    • You must use the Honeywell 1361 Transformer. • This configuration ONLY applies to the VISTA-10P, VISTA-15P, VISTA-20P control panels when used with the GSMV4G communicator.
  • Page 18: Backup Battery Connection

    GSMV4G/GSMVCN4G Installation and Setup Guide Shared Transformer Installation NOTE: When calculating the total load on the auxiliary power output of the control panel, budget 10mA for the communicator when using ECP mode. Backup Battery Connection The included battery (K14139) is used for backup in the event of power loss to the commu- nicator.
  • Page 19: Section 3: Programming The Communicator

    S E C T I O N Programming the Communicator • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • General Information The communicator is designed to deliver alarms via the GSM network to an AlarmNet central station when it is registered with a valid AlarmNet account.
  • Page 20: Using The Control Panel Programming Mode

    GSMV4G/GSMVCN4G Installation and Setup Guide 7720P Programmer Tool Connection Each key of the 7720P has two possible functions: a normal function and a Shift function. To perform a normal key function, simply press the desired key. To perform a Shift function, press the [Shift] key, and then press the appropriate key.
  • Page 21: Programming Conventions

    Section 3: Programming the Communicator Programming Conventions Programming is accomplished by answering a series of prompts (questions). Most prompts require only a [Y]es or [N]o response, while others require a numerical response (ID numbers, etc.). The current value is displayed on the second line in parentheses ( ). A "?" indicates an invalid entry.
  • Page 22 GSMV4G/GSMVCN4G Installation and Setup Guide PROMPTS OPTIONS DESCRIPTION [0-9, A-F, N, S, Enter Password This prompt is displayed if [Y] was pressed in Prompt 4 or 5. T, X, Y] Enter a 4-digit password (0-9, A-F, N, S, T, X, Y).
  • Page 23 Enter the 4-digit subscriber account number for the second central Sub ID station, 0001-9999. (????)_ [0001-9999] In ECP mode, the GSMV4G communicates with the control panel [01-30] Device Address using the ECP bus. Enter the appropriate ECP device address. For (03)_ VISTA-10 and VISTA-20 series control panels, use address 03.
  • Page 24 GSMV4G/GSMVCN4G Installation and Setup Guide PROMPTS OPTIONS DESCRIPTION •10 Minutes The old alarm time sets how long an undeliverable alarm is retried Old Alarm Time • 4 Hours for delivery to the central station. If the message is not validated, it 10 Minutes_ •...
  • Page 25: Ecp Status Codes

    Section 3: Programming the Communicator PROMPTS OPTIONS DESCRIPTION [Y], [N] Enables alarm reporting for zone 6. Enable Zn6 Y/N (N)_ If [N], skip to Prompt 35: "Enable Zn7." • (V+) Selects the triggering method for this zone input. Zn6 Trigger Type •...
  • Page 26: Alternative Mode Programming (Zone Trigger, 4204 And Two-4204)

    Zone Trigger Mode. 4204 Emulation Mode In 4204 Emulation Mode, the GSMV4G communicates with a compatible Honeywell VISTA series or First Alert control panel as though it were a 4204 Relay Module. If two 4204s are enabled in the communicator, it acts as two 4204s at consecutive device addresses. The control panel must be configured to recognize one or two 4204 relay modules accordingly.
  • Page 27 Section 3: Programming the Communicator 4204 Relay Outputs map to communicator zones as follows: First 4204 Zones Second 4204 Zones (device address entered in Prompt 14): (device address entered in Prompt 14, plus 1): Relay 1 = Zone 1 Relay 1 = Zone 5 Relay 2 = Zone 2 Relay 2 = Zone 6 Relay 3 = Zone 3...
  • Page 28: Alternative Mode Programming

    GSMV4G/GSMVCN4G Installation and Setup Guide Alternative Mode Programming Press the [ENTER] key to begin programming ollow the prompts for the mode of and f operation being programmed. NOTE: The central station can remotely block access to local Access to Prog device programming.
  • Page 29 Cover tamper will send email event 8. All communication device system events (such as power loss, low battery, Telco, etc.) are still sent to AlarmNet. Events used to send email messages are defined on the Honeywell Total Connect web site, and must correspond to events triggering the hardwired zones.
  • Page 30 GSMV4G/GSMVCN4G Installation and Setup Guide 4204/ ZONE PROMPTS OPTIONS DESCRIPTION 2-4204 TRIG. VISTA-128BP/250BP and FBP Applies only to [Y], [N] Direct Wire Series control panels. (N)_ If [N], and if Prompt 15: Remote Access is disabled, skip to Prompt 18: "Supervision."...
  • Page 31 Section 3: Programming the Communicator 4204/ ZONE PROMPTS OPTIONS DESCRIPTION 2-4204 TRIG. Sends a primary power loss report to the central [Y], [N] Pwr Loss Rpt Y/N station within 1-3 hours after its detection. A (Y)_ restore report is sent within 1-3 hours after power is restored.
  • Page 32 GSMV4G/GSMVCN4G Installation and Setup Guide 4204/ ZONE PROMPTS OPTIONS DESCRIPTION 2-4204 TRIG. • (V–), where a ground trigger causes an alarm for normally high connections (open collector, NO, NC) • (EOLR) End of Line Resistor, where the input is supervised by a 2K EOL resistor. The zone can be triggered by open collector, voltage trigger, NO, NC.
  • Page 33 Section 3: Programming the Communicator 4204/ ZONE PROMPTS OPTIONS DESCRIPTION 2-4204 TRIG. Enter the zone number to be used for open/close Zone Trig: [3-7] Open/Close Zone (arm/disarm) reports. This zone assignment must (0)_ 4204: [1-4] be unique from the Telco zone selected in Prompt 2-4204: Zone Trigger Mode: If any zone is programmed for [1-8]...
  • Page 34 GSMV4G/GSMVCN4G Installation and Setup Guide 4204/ ZONE PROMPTS OPTIONS DESCRIPTION 2-4204 TRIG. Reports alarms on zone 3 ONLY if the conditional [Y], [N] Rpt Zn3 ONLY if zone (zone 7 in zone trigger mode; zone 4 in 4204 Armed (N)_ mode;...
  • Page 35 Section 3: Programming the Communicator 4204/ ZONE PROMPTS OPTIONS DESCRIPTION 2-4204 TRIG. [Y], [N] Reports alarms on zone 6 ONLY if the conditional Rpt Zn6 ONLY if zone (zone 7 in zone trigger mode; zone 4 in 4204 Armed (N)_ mode;...
  • Page 36: Exiting Programming Mode

    GSMV4G/GSMVCN4G Installation and Setup Guide Exiting Programming Mode To exit the programming mode, press [N] in response to the "REVIEW?" question. Then press [Y] to the "Exit Prog Mode?" question. Upon exiting, the message "Checking Root File TX Path" will be displayed, and the configuration file at the server is updated to log the changes made.
  • Page 37: Section 4: Registration

    Log in and follow the on-screen prompts. If you are not signed up for this service, click on “Dealer Signup” from the login screen to gain access to the Honeywell web-based programming. Dealer Sign-Up Direct Link: https://services.alarmnet.com/AlarmNetDirectP_Sign-Up. You will be instructed how to proceed upon completing the sign-up form. Only one sign-up per dealer is required.
  • Page 38: Register Using The Tamper Switch

    GSMV4G/GSMVCN4G Installation and Setup Guide • Primary Central Station ID (two-digit hexadecimal number) • Primary Subscriber ID (four-digit number) • MAC ID and MAC CRC number (located on the box and inside the communicator) Once the communicator is registered, you may log out of the AlarmNet Direct website.
  • Page 39: Replacing An Existing Communicator

    Section 4: Registration Possible Errors Displayed if this is a repair/replacement, or an error was made in Registration BAD programming the Primary account information of the communicator Pri ID – Need PIN for an existing account. This prompt appears for 2 seconds. See the Replacing an existing communicator section below for further displays.
  • Page 40 GSMV4G/GSMVCN4G Installation and Setup Guide...
  • Page 41: Section 5: Programmer Keyboard Commands

    S E C T I O N Programmer Keyboard Commands • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • Programmer Keyboard Commands Programmer keyboard commands can be used to quickly view your connectivity settings and options.
  • Page 42: Gsm Status Displays

    GSMV4G/GSMVCN4G Installation and Setup Guide GSM Status Displays Operating with 3G/4G service Status Display Screen 1 PriRSSI 3/4G REG PriRSSI – Primary site RSSI level in dBm. -xxxdbm stat 3/4G – Communicator is on the 3G/4G network where “stat” can be: Good RSSI –20 to –90 dBm...
  • Page 43 Section 5: Programmer Keyboard Commands Operating with 2G service Status Display Screen 1 PriRSSI PriRSSI – Primary site level in dBm. -xxxdbm stat 2G – Communicator is on the2G network where “stat” can be: Good RSSI –20 to –89 dBm RSSI –90 to –98 dBm Marginal RSSI –99 to –104 dBm RSSI –105 to –150 dBm...
  • Page 44: System Status Displays

    GSMV4G/GSMVCN4G Installation and Setup Guide System Status Displays ECP Mode ECP 67 TmPB Displays the zone and system fault status. xx 5 ++ Press the [Space] key to go to the next field. Press the backspace [BS] key to go to the previous field.
  • Page 45 Section 5: Programmer Keyboard Commands System Status Displays – continued Battery Charger Battery Charger Indicates the battery charger circuit status ( either OK or NOT OK). Press the [Space] key to go to the next field. Press the backspace [BS] key to go to the previous field. Line Voltage Display Line Voltage The line voltage [this value is the peak voltage from the...
  • Page 46 GSMV4G/GSMVCN4G Installation and Setup Guide...
  • Page 47: Appendices

    Appendices • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • Appendix A: Summary of LED Operation...
  • Page 48 GSMV4G/GSMVCN4G Installation and Setup Guide...
  • Page 49: Appendix B: Central Station Messages

    Appendices Appendix B: Central Station Messages ECP Mode Zone and 4204 Modes Alarm Condition Alarm Code Restore Code Alarm Code Restore Code Power On / Reset E339 C08xx* 5551 5555 6 Tamper E341 C08xx* R341 C08xx* 5555 5551 7 5555 5553 7 (Compromise Indication) Power Loss E337 C08xx*...
  • Page 50 GSMV4G/GSMVCN4G Installation and Setup Guide...
  • Page 51: Appendix C: Glossary

    (e.g., www.yahoo.com) into numerical IP addresses (e.g., 204.17.25.1.). Digital Subscriber Line. Enhanced Console Protocol, which is a proprietary bus used in Honeywell control panels to communicate with keypads and peripheral devices. It uses four wires; power, ground, data in, data out.
  • Page 52 GSMV4G/GSMVCN4G Installation and Setup Guide...
  • Page 53 NOTES...
  • Page 54 NOTES...
  • Page 55 NOTES...
  • Page 56 NOTES...
  • Page 57 NOTES...
  • Page 58 NOTES...
  • Page 59 NOTES...
  • Page 60 NOTES...
  • Page 61 NOTES...
  • Page 62 NOTES...
  • Page 63 Summary of Connections NOTE: All circuits are supervised and all circuits are power limited except the battery. Communicator TB1 Wiring ECP Mode Zone Trigger Mode 4204 Mode Two – 4204 Mode AC 1 AC 1 AC 1 AC 1 AC 2 AC 2 AC 2 AC 2...
  • Page 64 For the latest documentation and online support information, please go to: http://www.security.honeywell.com/hsc/resources/MyWebTech/ WARRANTY For the latest warranty information, please go to: http://www.security.honeywell.com/hsc/resources/wa/ 2 Corporate Center Drive, Suite 100 P.O. Box 9040, Melville, NY 11747 Copyright  2012 Honeywell Ê800-11119ÀŠ International Inc. www.security.honeywell.com 800-11119 1/12 Rev. E...

This manual is also suitable for:

Gsmvcn4g

Table of Contents