hit counter script

Toe Summary Specification; Toe Security Functional Requirement Measures; Table 20: How Toe Sfr - Cisco Catalyst 4503-E Manual

Catalyst 4500 series
Hide thumbs Also See for Catalyst 4503-E:
Table of Contents

Advertisement

Cisco Cat4K NDPP ST
EDCS-1228241
6 TOE S
UMMARY
6.1

TOE Security Functional Requirement Measures

This section identifies and describes how the Security Functional Requirements identified
above are met by the TOE.
TOE SFRs
FAU_GEN.1
S
PECIFICATION
Table 20: How TOE SFRs are Met
How the SFR is Met
The TOE generates an audit record whenever an audited event
occurs. The types of events that cause audit records to be
generated include events related to the enforcement of
information flow policies, identification and authentication
related events, and administrative events (the specific events and
the contents of each audit record are listed in the table within the
FAU_GEN.1 SFR, "Auditable Events Table"). Each of the events
is specified in the audit record is in enough detail to identify the
user for which the event is associated (e.g. user identity, MAC
address, IP address), when the event occurred, where the event
occurred, the outcome of the event, and the type of event that
occurred. Additionally, the startup and shutdown of the audit
functionality is audited.
The audit trail consist of the individual audit records; one audit
record for each event that occurred. The audit record can contain
up to 80 characters and a percent sign (%), which follows the
time-stamp information. As noted above, the information
includes [at least] all of the required information. Additional
information can be configured and included if desired. Refer to
the Guidance documentation for configuration syntax and
information.
The logging buffer size can be configured from a range of 4096
(default) to 2147483647 bytes. It is noted, not make the buffer
size too large because the switch could run out of memory for
other tasks. Use the show memory privileged EXEC command to
view the free processor memory on the switch. However, this
value is the maximum available, and the buffer size should not be
set to this amount. Refer to the Guidance documentation for
configuration syntax and information.
The administrator can also configure a 'configuration logger' to
keep track of configuration changes made with the command-line
interface (CLI). The administrator can configure the size of the
configuration log from 1 to 1000 entries (the default is 100).
Refer to the Guidance documentation for configuration syntax
and information.
59
11 March 2014

Advertisement

Table of Contents
loading