Connection Guidelines for AC-Powered Systems

Connection Guidelines for AC-Powered Systems
For connecting the Cisco MDS 9396S switch AC power supplies to the site power source, follow these basic
guidelines:
• Each power supply should have its own dedicated branch circuit.
• For international, circuits should be sized according to local and national codes.
• The AC power receptacles used to plug in the chassis must be the grounding type. The grounding

SFP Transceiver Specifications

The Cisco MDS 9396S switch is compatible with SFP transceivers and cables that have LC connectors. Each
transceiver must match the transceiver on the other end of the cable in terms of wavelength, and the cable
must not exceed the stipulated cable length for reliable communications.
Cisco SFP transceivers provide the uplink interfaces, laser transmit (TX), and laser receive (RX), and they
support 850 to 1610 nm nominal wavelengths, depending upon the transceiver.
Use only Cisco SFP transceivers on the Cisco MDS 9396S switch. Each Cisco SFP transceiver is encoded
with model information that enables the switch to verify that the SFP transceiver meets the requirements for
the switch. For the list of supported SFP transceivers, see the Release Notes.
For details about SFP transceivers see the
For information about safety, regulatory, and standards compliance, see the
Information for the Cisco MDS 9000

Cisco Fibre Channel SFP+ Transceivers

The following table lists the Fibre Channel SFP+ transceivers available through Cisco Systems for the Cisco
MDS 9396S switch.
Table 4: Cisco Fibre Channel SFP + Transceivers for the Cisco MDS 9396S Switch
Part Number
DS-SFP-FC10G-SW
DS-SFP-FC10G-LW
DS-SFP-FC16G-SW
DS-SFP-FC16G-LW
Cisco MDS 9396S Multilayer Fabric Switch Hardware Installation Guide
52
conductors that connect to the receptacles should connect to protective earth ground at the service
equipment.
Cisco MDS 9000 Family Pluggable Transceivers Data
Family.
Description
Cisco MDS 10-Gbps Fibre Channel
SW SFP+, LC
Cisco MDS 10-Gbps Fibre Channel
LW SFP+, LC
Cisco MDS 4/8/16-Gbps Fibre
Channel SW SFP+, LC
Cisco MDS 4/8/16-Gbps Fibre
Channel LW SFP+, LC
Technical Specifications
Sheet.
Regulatory Compliance and Safety
Type