hit counter script

Disk Drive Bay Numbers; Drive Status - HP MSA 2040 Troubleshooting Manual

Hide thumbs Also See for MSA 2040:
Table of Contents

Advertisement

Disk Drive Bay Numbers

Figure 3 MSA 2040 SAN Array SFF enclosure
Figure 4 MSA 2040 SAN Array LFF or supported drive enclosure

Drive Status

Table 6 Drive Status
Status
Available
Failed
Global spare
Leftover
14
Troubleshooting HPE MSA 1040/2040 Storage
Displayed in the CLI or SMU
AVAIL
FAILED
GLOBAL SP
LEFTOVR
Description
The drive is available for use.
The drive is unusable and is replaced.
Reasons for this status include
excessive media errors, SMART
errors, drive hardware failures,
unsupported drives.
The drive is assigned as a global
spare.
The drive is leftover. It is missing
during a rescan of drives or it failed
due to Unrecoverable Read Errors
(UREs), SMART issues, or other
errors.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Msa 1040

Table of Contents

Save PDF