hit counter script

Advertisement

Quick Links

LGGAP Mode Manual
Model : GDC-345H
LG Electronics Inc.

Advertisement

Table of Contents
loading

Summary of Contents for LG GDC-345H

  • Page 1 LGGAP Mode Manual Model : GDC-345H LG Electronics Inc.
  • Page 2 LDK-24 WOTS GDC-345H Factory Mode Manual ISSUE 1.0 Revised History Date Issue Contents of Changes Software Version 2004-06-21 Initial Release Later than 2.0C This manual can be modified or updated due to production enhancement without prior notice. Unauthorized copy or partial plagiarism is prohibited by law.
  • Page 3: Table Of Contents

    LDK-24 WOTS GDC-345H Factory Mode Manual ISSUE 1.0 Contents General.......................... 4 1.1. Purpose ......................4 1.2. Looks....................... 4 User Interface......................5 2.1. LCD display ....................5 2.2. Buttons & Functions................... 5 Operating Procedure ....................6 3.1. Entering......................7 3.2. Exiting......................7 3.3.
  • Page 4: General

    1.1. Purpose This manual is for installer who needs service GDC-345H in detail. The installer is required to read “ LDK-24 Installation & Maintenance Manual” and “ GDC-345H User Guide” prior to this manual. Not proper operation against this manual cause critical damage to GDC-345H in hardware.
  • Page 5: User Interface

    ISSUE 1.0 2. User Interface 2.1. LCD display The LCD of GDC-345H has 8 icons and 2 x 12 dot matrix. The LCD shows various wireless states and displays visual feedback for the actions performed by user. Icon Description Antenna icon and RSSI icon...
  • Page 6: Operating Procedure

    LDK-24 WOTS GDC-345H Factory Mode Manual ISSUE 1.0 3. Operating Procedure This chapter describes the detail “ Factory Mode” operation of GDC-345H by LCD displays. Menu key LG GAP mode Input password (54427) Version Reset IPEI Valid SiteSurvey Password Cell TL [Figure.1 LGGAP Mode Menu Tree]...
  • Page 7: Entering

    2 0 0 4 . 0 6 . 1 9 3.4. Reset This submenu enables you to clear the EEPROM of GDC-345H. If you want initialize all data of EEPROM, press OK button. Else press C/R button C L E A R to cancel.
  • Page 8: Ipei

    For instance the value is determined as –80dBm and GDC-345H goes farther beyond the region of C u r : - 8 0 d B m which RSSI level is about –80dBm, then the warning tone is generated.
  • Page 9: Entering Cell Tool Mode

    In the Cell Tool Mode, LCD displays as left. The meaning of values is described at figure.2. To exit cell tool mode, turn off and on GDC-345H D ) S : 0 6 F : 0 1 or enter into this submenu to disable.
  • Page 10 LDK-24 WOTS GDC-345H Factory Mode Manual ISSUE 1.0 DECT slot number DECT frequency number 00, 02, 04, 06, 0A 00~09 D ) S : 0 6 F : 0 1 0 0 : - 4 2 d B m RSSI level Base station number [Figure.2 Cell Tool Mode LCD meaning]...