4. MECHANICAL SYSTEM
IV. PICK-UP ASSEMBLY
A. Pick-Up Assembly
1. Removing the Pick-Up Assembly
1) Remove the cassette from the copier.
2) Remove the right cover.
3) Pull off the roll q of the multi tray cover.
4) Detach the cable of the right door w from the
hook e; then, remove the right door.
Figure 4-401
5) Disconnect the connector r of the pick-up
assembly, and remove the grounding screw
t.
6) Remove the four screws u, and remove the
pick-up assembly y.
7
7
6
Figure 4-402
4–18
COPYRIGHT © 1996 CANON INC.
Download service manual and resetter printer at http://printer1.blogspot.com
1
3
2
4
7
5
7
CANON GP215/200 REV.0 JULY 1996 PRINTED IN JAPAN (IMPRIME AU JAPON)
2. Removing the Pick-
Up/Feeding/Separation Roller
1) Slide out the cassette.
2) Holding the knob assembly q, pull it off in the
axial direction.
Separation Roller
Feeding Roller
Pick-up Roller
Figure 4-403
3. Installing the Pick-
UP/Feeding/Separation Roller
1) Holding the knob assembly, push it in until a
click is heard.
1
1