3. OPERATIONS AND TIMING
F. Self Diagnosis of the Multi Output Tray-12
Code
The CPU (Q7) on the tray con-
E500
troller PCB or the communication
IC (Q11) is not operating normally.
• The bin unit feeding motor (M2)
E510
fails to rotate.
• The bin unit feeding motor clock
sensor (PI2) has a fault.
• The tray feeding motor (M6)
E515
fails to rotate.
• The tray feeding motor clock
sensor (PI6) has a fault.
• The tray shift motor (M7) fails to
E521
rotate.
• The tray position sensor (PI12)
has a fault.
The guide bar drive motor (M4)
E530
fails to rotate.
3–268
COPYRIGHT © 1996 CANON INC.
Download service manual and resetter printer at http://printer1.blogspot.com
Main cause
CANON GP215/200 REV.0 JULY 1996 PRINTED IN JAPAN (IMPRIME AU JAPON)
Description
An error has occurred in the communication
between the multi tray and the copier.
The bin unit feeding motor clock sensor (PI2)
does not receive clock signals 4.0 sec or
more after the bin unit feeding motor drive
signal (BFMD) has been generated.
The tray feeding motor clock sensor (PI6)
does not receive clock signals for 1 sec or
more after the tray feeding motor drive signal
(TFMD) has been generated.
The tray position sensor (PI12) does not turn
on or off 2.5 sec or more after the tray shift
motor drive signal has been generated.
The guide bar home position sensor (PI5)
does not turn on or off 2.5 sec or more after
the guide bar swing motor drive signal has
been generated.