2. Switching the Baud Rate, Drum Resistance Measurements, and Thick Paper
Mode
Item
BAUD RATE
ENV_SW
AGS NON
COPYRIGHT © 1996 CANON INC.
Download service manual and resetter printer at http://printer1.blogspot.com
*5* OPTION 2
BAUD RATE
: 0 <- (0)
ENV_SW
: 1 <- (1)
AGS NON
: 0 <- (0)
SPCL-PPR
: 0 <- (0)
SCAN_SEL
: 0 <- (0)
FAX_DOC_FEED : 0 <- (0)
+
Function
Use it to change the com-
munication speed of the
RS232C interface for ser-
vicing.
• Be sure to set it to '1' if
you have selected a
cassette exclusively for
envelopes.
The switch determines
whether the machine
should recognize an
envelope cassette.
Use it to specify whether
the density correction
curve should be modified
based on the results of
measuring the resistance
of the photosensitive
drum.
CANON GP215/200 REV.0 JULY 1996 PRINTED IN JAPAN (IMPRIME AU JAPON)
3. OPERATIONS AND TIMING
CANCEL
OK
Description
0: 19200 baud
1: 9600 baud
0: If the paper size dial of the cassette is set
to the envelope index, the cassette will not
be identified as an envelope cassette.
1: If the paper size dial of the cassette is set
to the envelope index, the cassette will be
identified as an envelope cassette.
Default:1
0: change the density correction curve based
on the results of measuring the resistance
of the photosensitive drum.
1: do not change the density correction curve.
Guide
If the results of making adjustments
according to the Basic Image Adjustment
Procedure are not good, execute the 15th
screen (*4*).
If the indicated value is far off the target
value, set the item in this mode to '1' so nor-
mal images may be obtained.
However, if such a problem occurs, you
must suspect a fault in the image processor
PCB, DC controller PCB, or composite
power supply PCB.