hit counter script

Test 3 Motor Test - LG DGS2028EKD Service Manual

Electric & gas dryer
Hide thumbs Also See for DGS2028EKD:
Table of Contents

Advertisement

Test 3
Motor test
Caution
Trouble Symptom
Measurement Condition
1
Idler Switch Lever Idler Switch
Before measuring resistance, be sure to turn power off, and do voltage discharge.
(When discharging, contact the metal plug of power cord with earth line.)
Drum will not rotate; no fan will function; no heater will work.
Turn the dryer's power off, then measure resistance.
Is resistance below 3Ω between Connector
WH
(White wire) and BL2-
Measure while door is closed.
Is resistance below 3Ω between Connector
WH
(White wire) and BL2-
Measure while door is closed.
Is resistance below 3Ω between Connector
BL2-
(Yellow wire) and BL2-
Is resistance below 1Ω between terminals
of Outlet Thermostat attached to blower housing?
Does Idle Switch attached to Motor Bracket
operate Level by drum belt?
(Not operating Lever is normal.)
Is resistance below 1Ω between Idler Switch
terminals?
• Check Motor. (Refer to 'Motor Diagram & Check')
• Check if Control Connector is contacted.
(Brown wire)?
NO
(Yellow wire)?
YES
(Brown wire)?
NO
YES
YES
22
• Replace Control.
YES
(Relay check)
• Check Controller
connector.
• Check if Door flame
presses door switch
knob.
NO
• Check Door Switch.
• Check Harness
connection.
• Replace Control.
YES
(Relay check)
• Check Controller
connector.
• Replace Outlet
• Thermostat.
NO
(Refer to
'Component')
• Check Idler Assembly.
• Drum Belt cuts off
• Drum Belt takes off
YES
from Motor Pulley.
• Replace Idler
NO
Switch.

Advertisement