CHAPTER 8 PAPER DECK
8) Insert a hex wrench [11] into the home
in the lifter drive shaft [10] to hold it in
place.
If you failed to hold the lifter
drive shaft as shown, the lifter
cable will become slack when
you move the lifter motor unit.
9) Remove the five screws [12], and detach
the lifter motor unit [13].
8-36 P
COPYRIGHT © 2000 CANON INC.
[10]
F08-303-12
[12]
[13]
F08-303-13