4) If you have replaced the transfer charg-
ing wire or the transfer/separation
charging assembly be sure to execute
the following in service mode to clean
the wire:
COPIER>FUNCTION>CLEANING>
WIRE-CLN.
If you have replaced the separation
charging wire or the separation charging
assembly, be sure to execute 'wire
cleaning' in user mode. (If the surface
temperature of the fixing upper roller is
100°C or lower, you need not execute
this mode, as the wire will be cleaned
automatically.)
Further, be sure to use a
strengthened polishing pad
(blue holder) as the cleaning
pad.
COPYRIGHT © 2000 CANON INC.
2000 2000 2000 2000
CANON iR5000/iR6000 REV.0 JULY 2000
CHAPTER 4 IMAGE FORMATION SYSTEM
4-65 P